KY-129 over UNNAMED STREAM
Map
Coordinates:
+36.50250, -88.8658336°30'09" N, 88°51'57" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-129 over UNNAMED STREAM |
Structure number: | 038B00072N |
Old structure number: | 038*0129*B0072 (from 1992 edition) |
Location: | 100 FT E OF CLEVELAND ST |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 22.0 ft. [6.7 m] |
Total length: | 24.0 ft. [7.3 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 24.0 ft. [7.3 m] |
Owner: | State Highway Agency [01] |
Year built: | 1966 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,381 [as of 2017] |
Truck traffic: | 11% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 79.9 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $72,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 2381 | 79.9 |
May 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 2435 | 79.8 |
May 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 2990 | 79.6 |
May 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 2790 | 79.7 |
May 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 3100 | 79.5 |
May 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 2920 | 79.6 |
June 2006 | Fair | Satisfactory | Satisfactory | Satisfactory | 3710 | 79.2 |
May 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 3721 | 79.2 |
May 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 4320 | 78.9 |
May 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 4320 | 75.9 |
May 1996 | Fair | Satisfactory | Satisfactory | Satisfactory | 4320 | 75.9 |
May 1994 | Good | Good | Good | Good | 2638 | 76.7 |
May 1992 | Good | Good | Good | Good | 2638 | 76.7 |
May 1990 | Good | Good | Good | Good | 2638 | 76.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 192 | 0 | 190 | 2 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 574 | 0 | 574 | 0 | 0 |
Substructure |
Timber Column | each | 9 | 0 | 9 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 50 | 0 | 50 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 48 | 0 | 48 | 0 | 0 |
Steel Protective Coating | sq. ft. | 240 | 0 | 240 | 0 | 0 |