Share:

KY-467 over CARVER CREEK IN SPARTA

Map

Coordinates:
+38.67611, -84.90778
38°40'34" N, 84°54'28" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-467 over CARVER CREEK IN SPARTA
Structure number:039B00031N
Old structure number:039*0467*B0031 (from 1992 edition)
Location:.10 MI WEST OF JCT KY 35
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:14.1 ft. [4.3 m]
Total length:30.8 ft. [9.4 m]
Roadway width between curbs:35.8 ft. [10.9 m]
Deck width edge-to-edge:47.9 ft. [14.6 m]
Owner:State Highway Agency [01]
Year built:1954
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:533 [as of 2012]
Truck traffic:15% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:71.7

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
July 2017Fair5 out of 1053371.7
July 2015Fair5 out of 1053358.3
July 2013Fair5 out of 1059358.3
July 2011Fair5 out of 1062658.3
August 2009Fair5 out of 1063158.3
December 2007Fair5 out of 1071058.3
August 2005Good7 out of 1057968.4
September 2003Good7 out of 10127874.9
August 2001Good7 out of 10127874.9
July 1999Good7 out of 10127874.9
August 1997Good7 out of 10127874.9
July 1995Good7 out of 1040183.5
July 1993Good7 out of 1043883.4
July 1991Good7 out of 1043883.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.964135200