Share:

KY-1355 over TURNERS BRANCH

Map

Coordinates:
+37.68611, -84.56861
37°41'10" N, 84°34'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-1355 over TURNERS BRANCH
Structure number:040B00027N
Old structure number:040*1355*B0027 (from 1992 edition)
Location:2 MI E OF JCT KY 1971
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:23.0 ft. [7.0 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:22.6 ft. [6.9 m]
Deck width edge-to-edge:24.3 ft. [7.4 m]
Owner:State Highway Agency [01]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:352 [as of 2016]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:70.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairGoodFairSatisfactory35270.7
December 2015FairGoodFairSatisfactory37970.6
November 2013FairGoodFairSatisfactory37970.8
November 2011FairSatisfactoryFairSatisfactory51870.7
November 2009FairSatisfactoryFairFair47670.7
November 2007FairSatisfactoryFairFair48770.7
November 2005FairSatisfactoryFairFair37870.8
November 2003FairSatisfactorySatisfactoryFair24775.4
November 2001FairSatisfactorySatisfactorySatisfactory24786.4
November 1999FairSatisfactorySatisfactoryGood24786.4
November 1997FairSatisfactorySatisfactoryGood24786.4
November 1995FairSatisfactorySatisfactoryGood22085.4
November 1993FairSatisfactoryGoodGood22085.4
November 1991FairSatisfactoryGoodGood22085.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.2081761697
Deck
Prestressed Concrete Top Flangesq. ft.630630000
Wearing Surfacessq. ft.592592000
Substructure
Reinforced Concrete Abutmentlinear ft.8378320
Reinforced Concrete Pile Cap/Footinglinear ft.6158210
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.5252000
Steel Protective Coatingsq. ft.260260000