SCOTTS FORK RD over SCOTTS FORK
Map
Coordinates:
+37.70778, -84.5252837°42'28" N, 84°31'31" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SCOTTS FORK RD over SCOTTS FORK |
Structure number: | 040C00041N |
Location: | 1.3 MI W JCT KY 39 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 27.6 ft. [8.4 m] |
Total length: | 34.1 ft. [10.4 m] |
Roadway width between curbs: | 13.1 ft. [4.0 m] |
Deck width edge-to-edge: | 18.0 ft. [5.5 m] |
Skew angle: | 45° |
Owner: | County Highway Agency [02] |
Year built: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Good |
Status: | Posted for load [P] |
Average daily traffic: | 75 [as of 2006] |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 75.8 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $93,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Good | Very Good | Very Good | Good | 75 | 75.8 |
February 2016 | Good | Good | Good | Good | 75 | 73.8 |
November 2013 | Good | Good | Good | Good | 75 | 62.9 |
November 2011 | Fair | Satisfactory | Good | Satisfactory | 75 | 59.4 |
November 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 75 | 59.4 |
October 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 76 | 59.4 |
November 2005 | Fair | Satisfactory | Fair | Fair | 50 | 49.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 204 | 204 | 0 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 617 | 617 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 442 | 442 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 72 | 72 | 0 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 67 | 50 | 17 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 68 | 0 | 68 | 0 | 0 |
Steel Protective Coating | sq. ft. | 340 | 0 | 0 | 340 | 0 |