WALLACETOWN RD. over PAINT LICK CREEK
Map
Coordinates:
+37.57028, -84.3652837°34'13" N, 84°21'55" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | WALLACETOWN RD. over PAINT LICK CREEK |
Structure number: | 040C00046N |
Location: | 50' WEST OF - KY 21 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 32.5 ft. [9.9 m] |
Total length: | 36.1 ft. [11.0 m] |
Roadway width between curbs: | 14.8 ft. [4.5 m] |
Deck width edge-to-edge: | 16.1 ft. [4.9 m] |
Owner: | County Highway Agency [02] |
Year built: | 1993 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 128 [as of 2006] |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 81.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Satisfactory | Good | Good | 128 | 81.5 |
November 2015 | Good | Good | Good | Good | 128 | 81.5 |
November 2013 | Good | Good | Good | Good | 128 | 80.5 |
November 2011 | Fair | Satisfactory | Good | Satisfactory | 128 | 80.5 |
November 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 128 | 80.5 |
October 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 132 | 80.5 |
November 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 90 | 84.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 144 | 144 | 0 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 582 | 562 | 20 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 65 | 62 | 3 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 46 | 45 | 1 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 68 | 68 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 340 | 340 | 0 | 0 | 0 |