BOONES CREEK RD over BOONE CREEK
Map
Coordinates:
+37.64222, -84.6275037°38'32" N, 84°37'39" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | BOONES CREEK RD over BOONE CREEK |
Structure number: | 040C00049N |
Location: | .7 MI.N. JCT KY 52 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 26.9 ft. [8.2 m] |
Total length: | 29.9 ft. [9.1 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 23.6 ft. [7.2 m] |
Owner: | County Highway Agency [02] |
Year built: | 1995 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 164 [as of 2012] |
Truck traffic: | 7% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 77.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Satisfactory | Good | Satisfactory | 164 | 77.4 |
November 2015 | Fair | Good | Good | Satisfactory | 164 | 78.8 |
November 2013 | Fair | Good | Good | Satisfactory | 170 | 80.3 |
November 2011 | Fair | Satisfactory | Good | Satisfactory | 170 | 86.4 |
November 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 170 | 86.4 |
October 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 175 | 86.4 |
November 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 125 | 86.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 180 | 179 | 1 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 707 | 662 | 45 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 70 | 61 | 9 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 27 | 27 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 56 | 56 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 280 | 280 | 0 | 0 | 0 |