Share:

KY-1913 over SUBLETT BRANCH

Map

Coordinates:
+37.19667, -85.36806
37°11'48" N, 85°22'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-1913 over SUBLETT BRANCH
Structure number:044B00024N
Old structure number:044*1913*B0024 (from 1992 edition)
Location:.70 MI WEST OF TAYLOR CL
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:14.1 ft. [4.3 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:17.4 ft. [5.3 m]
Deck width edge-to-edge:2.0 ft. [0.6 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1954
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:270 [as of 2012]
Truck traffic:7% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:65.7

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
October 2016Good7 out of 1027065.7
October 2014Good7 out of 1036865.7
October 2013Good7 out of 1027065.7
October 2011Good7 out of 1047165.7
October 2010Good7 out of 1046165.7
October 2009Good7 out of 1045765.7
October 2007Good7 out of 1045765.7
October 2005Good7 out of 1045278.2
October 2003Good7 out of 1047065.4
October 2001Good7 out of 1047065.4
October 1999Good7 out of 1047065.4
October 1997Good7 out of 1047065.4
October 1995Good7 out of 1027265.4
October 1993Good7 out of 1027263.5
October 1991Good7 out of 1027263.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.6206200