Bramlett-Kemp Road over Russell Creek
Map
Coordinates:
+37.13694, -85.4580637°08'13" N, 85°27'29" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Bramlett-Kemp Road over Russell Creek |
Structure number: | 044C00041N |
Location: | @Adai CL2MISof Jct KY 487 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 73.2 ft. [22.3 m] |
Total length: | 124.0 ft. [37.8 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 25.6 ft. [7.8 m] |
Owner: | County Highway Agency [02] |
Year built: | 2007 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 60 [as of 2011] |
Truck traffic: | 7% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 97.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Satisfactory | Good | Very Good | 60 | 97.0 |
April 2015 | Fair | Satisfactory | Good | Very Good | 60 | 97.0 |
April 2014 | Fair | Satisfactory | Good | Very Good | 60 | 97.0 |
April 2012 | Good | Good | Very Good | Very Good | 60 | 75.0 |
April 2010 | Good | Good | Very Good | Very Good | - | 75.0 |
April 2008 | Good | Very Good | Very Good | Very Good | 94 | 74.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 744 | 741 | 3 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 3,174 | 0 | 3,174 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 23 | 23 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 52 | 52 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 29 | 29 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 248 | 248 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,240 | 1,240 | 0 | 0 | 0 |