Share:

KY 573 over LITTLE SIX MILE CREEK

Map

Coordinates:
+38.37139, -84.99694
38°22'17" N, 84°59'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY 573 over LITTLE SIX MILE CREEK
Structure number:052B00042N
Old structure number:052*0573*B0042 (from 1992 edition)
Location:1.6 MI W OF JCT KY 561
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:17.1 ft. [5.2 m]
Total length:53.8 ft. [16.4 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1955
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:223 [as of 2016]
Truck traffic:3% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:75.9

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
July 2017Fair6 out of 1022375.9
July 2015Fair6 out of 1026167.9
July 2013Fair6 out of 1026167.9
July 2011Fair6 out of 1032367.8
October 2009Fair6 out of 1027469.4
December 2007Fair6 out of 1025769.4
October 2005Fair6 out of 1029269.4
August 2003Fair6 out of 1016182.6
July 2001Fair6 out of 1016182.6
July 1999Good7 out of 1016182.6
July 1997Good7 out of 1016182.6
July 1995Good7 out of 1038484.3
July 1993Good7 out of 1038484.3
July 1991Good7 out of 1038484.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.1178710200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.108001080