CRESSMONT RD over LOWER SINKING CREEK
Map
Coordinates:
+37.53694, -83.8102837°32'13" N, 83°48'37" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | CRESSMONT RD over LOWER SINKING CREEK |
Structure number: | 065C00013N |
Location: | 2 MI W OF JCT KY 399 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 75.1 ft. [22.9 m] |
Total length: | 80.1 ft. [24.4 m] |
Roadway width between curbs: | 22.6 ft. [6.9 m] |
Deck width edge-to-edge: | 24.3 ft. [7.4 m] |
Skew angle: | 30° |
Owner: | County Highway Agency [02] |
Year built: | 1979 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 200 [as of 2006] |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 88.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Satisfactory | Good | Good | 200 | 88.3 |
March 2015 | Fair | Satisfactory | Good | Good | 200 | 88.3 |
March 2013 | Fair | Satisfactory | Good | Good | 200 | 88.3 |
January 2012 | Fair | Satisfactory | Good | Good | 200 | 88.3 |
January 2010 | Fair | Satisfactory | Good | Good | 200 | 88.3 |
December 2007 | Fair | Satisfactory | Good | Good | 200 | 88.3 |
November 2005 | Good | Good | Good | Good | 200 | 88.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 640 | 640 | 0 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 1,944 | 1,847 | 97 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 84 | 84 | 0 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 3 | 3 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 160 | 160 | 0 | 0 | 0 |