US-62 over CUMBERLAND RIVER
Map
Coordinates:
+37.03028, -88.2269437°01'49" N, 88°13'37" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US-62 over CUMBERLAND RIVER |
Structure number: | 070B00065N |
Old structure number: | 070*0062*B0065 (from 1992 edition) |
Location: | OVER CUMBERLAND RIVER |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 700.2 ft. [213.4 m] |
Total length: | 1466.9 ft. [447.1 m] |
Roadway width between curbs: | 24.9 ft. [7.6 m] |
Deck width edge-to-edge: | 29.2 ft. [8.9 m] |
Vertical clearance above deck: | 16.1 ft. [4.9 m] |
Vertical clearance below bridge: | 39.4 ft. [12.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1952 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 5,985 [as of 2015] |
Truck traffic: | 18% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | None present but re-evaluation suggested [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 48.0 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $13,425,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Good | Satisfactory | Fair | 5985 | 48.0 |
April 2016 | Fair | Good | Satisfactory | Fair | 5985 | 48.0 |
April 2015 | Fair | Good | Satisfactory | Fair | 7640 | 48.0 |
May 2013 | Fair | Good | Satisfactory | Fair | 6775 | 48.0 |
April 2013 | Fair | Good | Satisfactory | Fair | 6794 | 48.0 |
April 2012 | Fair | Good | Satisfactory | Fair | 6950 | 48.8 |
April 2011 | Fair | Good | Satisfactory | Fair | 7180 | 48.8 |
March 2010 | Fair | Good | Satisfactory | Fair | 7640 | 48.8 |
April 2009 | Fair | Good | Satisfactory | Fair | 7040 | 48.8 |
March 2008 | Poor | Poor | Satisfactory | Fair | 5870 | 45.8 |
June 2004 | Fair | Fair | Satisfactory | Fair | 6142 | 39.8 |
April 1999 | Fair | Fair | Satisfactory | Fair | 8814 | 35.2 |
May 1998 | Fair | Fair | Satisfactory | Fair | 8814 | 35.2 |
April 1997 | Fair | Fair | Satisfactory | Fair | 9395 | 35.2 |
May 1996 | Fair | Fair | Satisfactory | Fair | 9395 | 35.2 |
April 1995 | Fair | Satisfactory | Satisfactory | Satisfactory | 5001 | 46.2 |
April 1994 | Fair | Satisfactory | Satisfactory | Satisfactory | 5001 | 45.5 |
April 1992 | Good | Good | Good | Good | 5001 | 45.5 |
April 1991 | Good | Good | Good | Good | 5001 | 45.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 5,868 | 0 | 5,848 | 20 | 0 |
Steel Protective Coating | sq. ft. | 44,023 | 43,523 | 340 | 160 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 42,832 | 0 | 42,832 | 0 | 0 |
Wearing Surfaces | sq. ft. | 36,581 | 36,581 | 0 | 0 | 0 |
Superstructure |
Steel Truss | linear ft. | 700 | 0 | 700 | 0 | 0 |
Steel Protective Coating | sq. ft. | 27,452 | 14,968 | 3,742 | 3,742 | 5,000 |
Steel Floor Beam | linear ft. | 1,856 | 0 | 1,836 | 20 | 0 |
Steel Protective Coating | sq. ft. | 18,304 | 17,704 | 200 | 200 | 200 |
Steel Pin or Pin & Hangar Assembly | each | 16 | 0 | 16 | 0 | 0 |
Steel Protective Coating | sq. ft. | 68 | 0 | 48 | 20 | 0 |
Steel Gusset Plate | each | 58 | 0 | 58 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,240 | 0 | 2,240 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 22 | 0 | 22 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 58 | 0 | 58 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 204 | 0 | 204 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 156 | 0 | 156 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 8 | 8 | 0 | 0 | 0 |
Movable Bearing | each | 28 | 20 | 8 | 0 | 0 |
Steel Protective Coating | sq. ft. | 305 | 225 | 80 | 0 | 0 |
Fixed Bearing | each | 20 | 20 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 181 | 181 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 2,934 | 0 | 2,894 | 40 | 0 |
Steel Protective Coating | sq. ft. | 14,660 | 11,460 | 3,000 | 200 | 0 |