Share:

BORES RD over LITTLE WHIPPORWILL CK

Map

Coordinates:
+36.73028, -86.83333
36°43'49" N, 86°49'60" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BORES RD over LITTLE WHIPPORWILL CK
Structure number:071C00062N
Location:1.8 MI E. JCT KY 431
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:37.1 ft. [11.3 m]
Total length:40.4 ft. [12.3 m]
Roadway width between curbs:23.0 ft. [7.0 m]
Deck width edge-to-edge:23.0 ft. [7.0 m]
Owner:County Highway Agency [02]
Year built:1986
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:122 [as of 2006]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:80.9 tons [73.5 metric tons]
Inventory rating:47.9 tons [43.5 metric tons]
Sufficiency rating:75.4

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201575.4FairGoodGoodFair-122
June 201386.4GoodGoodGoodGood-122
December 201176.9GoodGoodGoodGood-122
June 200976.9GoodGoodGoodGoodFO122
June 200776.9GoodGoodGoodGoodFO122
June 200581.0GoodGoodGoodGood-70

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.284281300
Deck
Prestressed Concrete Top Flangesq. ft.9328884400
Substructure
Reinforced Concrete Abutmentlinear ft.49182830