KY-700 over INDIAN CREEK
Map
Coordinates:
+36.80222, -84.3752836°48'08" N, 84°22'31" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-700 over INDIAN CREEK |
Structure number: | 074B00026N |
Old structure number: | 074*0700*B0026 (from 1992 edition) |
Location: | 2.3 MI S OF JCT KY 1045 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 71.5 ft. [21.8 m] |
Total length: | 169.0 ft. [51.5 m] |
Roadway width between curbs: | 25.6 ft. [7.8 m] |
Deck width edge-to-edge: | 26.9 ft. [8.2 m] |
Skew angle: | 20° |
Owner: | State Highway Agency [01] |
Year built: | 1982 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: February 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 301 [as of 2015] |
Truck traffic: | 11% of total traffic |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 42.6 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2018 | Poor | Poor | Poor | Satisfactory | 301 | 42.6 |
February 2016 | Poor | Poor | Poor | Satisfactory | 212 | 47.2 |
February 2014 | Poor | Poor | Poor | Satisfactory | 235 | 47.2 |
February 2012 | Poor | Poor | Poor | Satisfactory | 278 | 44.4 |
February 2010 | Fair | Fair | Fair | Satisfactory | 265 | 81.0 |
February 2008 | Fair | Fair | Fair | Satisfactory | 221 | 85.5 |
February 2006 | Fair | Satisfactory | Satisfactory | Very Good | 203 | 97.5 |
February 2004 | Good | Good | Good | Very Good | 271 | 93.0 |
February 2002 | Good | Good | Very Good | Very Good | 271 | 93.0 |
February 2000 | Good | Good | Good | Very Good | 271 | 93.0 |
February 1998 | Good | Good | Very Good | Very Good | 271 | 93.0 |
February 1996 | Good | Good | Very Good | Very Good | 271 | 93.0 |
February 1994 | Good | Good | Very Good | Very Good | 164 | 97.7 |
February 1992 | Good | Good | Very Good | Very Good | 164 | 97.7 |
February 1990 | Good | Good | Very Good | Very Good | 164 | 97.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 1,522 | 522 | 349 | 365 | 286 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 4,566 | 2,249 | 1,912 | 405 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 1 | 3 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 76 | 64 | 12 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 60 | 45 | 12 | 3 | 0 |
Joints |
Pourable Joint | linear ft. | 54 | 0 | 0 | 22 | 32 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 338 | 338 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,690 | 1,690 | 0 | 0 | 0 |