Share:

KY-3407 over WOLF CREEK

Map

Coordinates:
+37.79750, -82.41972
37°47'51" N, 82°25'11" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-3407 over WOLF CREEK
Structure number:080B00028N
Old structure number:080*3407*B0028 (from 1992 edition)
Location:.01 MI.S JCT KY 1714
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:77.1 ft. [23.5 m]
Total length:149.9 ft. [45.7 m]
Roadway width between curbs:12.5 ft. [3.8 m]
Deck width edge-to-edge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1981
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:478 [as of 2017]
Truck traffic:11% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:49.8
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$315,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018PoorFairPoorFair47849.8
August 2016FairSatisfactoryFairFair48649.0
August 2014FairSatisfactoryFairFair63946.6
August 2012FairSatisfactoryFairFair62446.9
August 2010FairSatisfactoryFairSatisfactory72045.4
August 2008FairSatisfactoryFairSatisfactory70745.6
August 2006FairGoodFairSatisfactory79444.3
August 2004FairGoodFairSatisfactory70740.4
March 2002FairGoodFairSatisfactory26647.2
March 2000FairGoodFairSatisfactory26642.7
April 1998FairGoodSatisfactoryGood26654.8
March 1996FairGoodSatisfactoryGood26656.9
August 1994FairGoodSatisfactoryGood30065.0
July 1992GoodGoodGoodGood30065.0
July 1990GoodGoodGoodGood30065.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.6000056040
Steel Protective Coatingsq. ft.11000
Deck
Reinforced Concrete Decksq. ft.2,4741,8745001000
Wearing Surfacessq. ft.1,8751,55631900
Substructure
Masonry Pier Walllinear ft.38020162
Reinforced Concrete Abutmentlinear ft.3303300
Steel Pileeach60060
Steel Protective Coatingsq. ft.11000
Steel Pier Caplinear ft.80420308
Steel Protective Coatingsq. ft.22000
Reinforced Concrete Pier Caplinear ft.3603600
Joints
Pourable Jointlinear ft.3300330
Bearings
Fixed Bearingeach2000020
Steel Protective Coatingsq. ft.11000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.150015000
Steel Protective Coatingsq. ft.750075000