MULLET BR RD over COLDWATER CREEK
Map
Coordinates:
+37.80194, -82.5200037°48'07" N, 82°31'12" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | MULLET BR RD over COLDWATER CREEK |
Structure number: | 080C00020N |
Location: | .1 MI W KY 908 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 24.9 ft. [7.6 m] |
Total length: | 32.2 ft. [9.8 m] |
Roadway width between curbs: | 13.8 ft. [4.2 m] |
Deck width edge-to-edge: | 15.4 ft. [4.7 m] |
Skew angle: | 30° |
Owner: | County Highway Agency [02] |
Year built: | 1970 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 140 [as of 2011] |
Truck traffic: | 11% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 71.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Satisfactory | Good | Satisfactory | 140 | 71.7 |
February 2017 | Fair | Satisfactory | Good | Satisfactory | 100 | 75.1 |
February 2016 | Fair | Satisfactory | Good | Satisfactory | 100 | 75.1 |
August 2014 | Fair | Satisfactory | Good | Satisfactory | 100 | 75.1 |
August 2013 | Fair | Satisfactory | Good | Satisfactory | 100 | 75.1 |
August 2012 | Fair | Good | Good | Fair | 100 | 63.9 |
August 2011 | Fair | Good | Good | Fair | 100 | 63.9 |
August 2010 | Fair | Good | Good | Fair | 100 | 63.9 |
August 2008 | Fair | Good | Good | Satisfactory | 100 | 75.1 |
November 2007 | Fair | Good | Good | Satisfactory | 100 | 75.1 |
August 2005 | Fair | Good | Good | Satisfactory | 100 | 75.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 160 | 148 | 6 | 6 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 496 | 471 | 25 | 0 | 0 |
Wearing Surfaces | sq. ft. | 448 | 426 | 22 | 0 | 0 |
Substructure |
Timber Column | each | 12 | 0 | 12 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 34 | 0 | 34 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 64 | 64 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 320 | 320 | 0 | 0 | 0 |