APPLEGATE ROAD over BUCK CREEK
Map
Coordinates:
+37.47333, -83.6777837°28'24" N, 83°40'40" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | APPLEGATE ROAD over BUCK CREEK |
Structure number: | 095C00006N |
Location: | .1 MI W-MAIN ST-KY 11 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 35.1 ft. [10.7 m] |
Total length: | 40.0 ft. [12.2 m] |
Roadway width between curbs: | 13.5 ft. [4.1 m] |
Deck width edge-to-edge: | 15.4 ft. [4.7 m] |
Owner: | County Highway Agency [02] |
Year built: | 1973 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 100 [as of 2006] |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 70.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Satisfactory | Good | Fair | 100 | 70.0 |
March 2016 | Fair | Satisfactory | Good | Fair | 100 | 70.0 |
March 2014 | Fair | Satisfactory | Good | Fair | 100 | 58.7 |
March 2012 | Fair | Satisfactory | Good | Fair | 100 | 58.7 |
March 2010 | Fair | Satisfactory | Good | Fair | 100 | 58.7 |
March 2008 | Fair | Good | Good | Fair | 100 | 58.7 |
March 2006 | Fair | Good | Good | Fair | 100 | 58.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 148 | 0 | 148 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 617 | 592 | 25 | 0 | 0 |
Wearing Surfaces | sq. ft. | 544 | 544 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 40 | 22 | 18 | 0 | 0 |