Share:

KY-177 over SOU.FK.LICKING R.@BUTLER

Map

Coordinates:
+38.78972, -84.36722
38°47'23" N, 84°22'02" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-177 over SOU.FK.LICKING R.@BUTLER
Structure number:096B00001N
Old structure number:096*0177*B0001 (from 1992 edition)
Location:1.0 MI WEST OF JCT US 27
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:150.9 ft. [46.0 m]
Total length:630.0 ft. [192.0 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Vertical clearance above deck:15.4 ft. [4.7 m]
Owner:State Highway Agency [01]
Year built:1936
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:2,830 [as of 2017]
Truck traffic:8% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:41.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairSatisfactoryFairSatisfactory283041.5
April 2017FairSatisfactoryFairSatisfactory257948.4
April 2016FairSatisfactoryFairSatisfactory257948.4
February 2016FairSatisfactoryFairSatisfactory257948.4
February 2015FairSatisfactoryFairSatisfactory288747.4
February 2014FairSatisfactoryFairSatisfactory284147.5
February 2013FairSatisfactoryFairSatisfactory280047.7
February 2012FairSatisfactoryFairSatisfactory277047.8
February 2011FairSatisfactoryFairSatisfactory258048.4
March 2009FairSatisfactoryFairSatisfactory225049.4
March 2008FairFairFairSatisfactory337044.7
March 2005FairFairSatisfactorySatisfactory299149.7
March 2004FairSatisfactoryGoodSatisfactory162156.1
January 2002FairGoodGoodSatisfactory162156.1
June 2000FairSatisfactoryGoodSatisfactory162157.1
February 1998FairGoodGoodSatisfactory162157.1
May 1996FairGoodGoodSatisfactory132257.8
March 1994FairGoodGoodSatisfactory122865.2
January 1992FairGoodGoodSatisfactory122865.2
November 1991FairGoodGoodSatisfactory122865.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.50440410000
Steel Protective Coatingsq. ft.6,8886,38850000
Steel Stringerlinear ft.2,2602,15185024
Steel Protective Coatingsq. ft.10,1709,95022000
Deck
Reinforced Concrete Decksq. ft.18,90018,70020000
Wearing Surfacessq. ft.15,12514,92520000
Superstructure
Steel Trusslinear ft.45236175160
Steel Protective Coatingsq. ft.16,77016,770000
Steel Floor Beamlinear ft.8407900500
Steel Protective Coatingsq. ft.7,5606,80076000
Steel Gusset Plateeach72522000
Steel Protective Coatingsq. ft.20,68820,688000
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.90603000
Reinforced Concrete Pier Caplinear ft.1841681240
Joints
Strip Seal Jointlinear ft.120606000
Compression Jointlinear ft.6060000
Bearings
Movable Bearingeach1815300
Steel Protective Coatingsq. ft.126126000
Fixed Bearingeach66000
Steel Protective Coatingsq. ft.5151000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,2601,2015108