Share:

JAGG RD over BUCK LICK CREEK

Map

Coordinates:
+38.73944, -84.49306
38°44'22" N, 84°29'35" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:JAGG RD over BUCK LICK CREEK
Structure number:096C00078N
Location:.5 MI.SE JCT KNOXVILLERD
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:11.2 ft. [3.4 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:17.1 ft. [5.2 m]
Deck width edge-to-edge:18.0 ft. [5.5 m]
Owner:County Highway Agency [02]
Year built:1970
Year reconstructed:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:30 [as of 2006]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:72.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018FairVery GoodVery GoodFair3072.5
August 2016FairVery GoodVery GoodFair3072.5
August 2015FairVery GoodVery GoodFair3072.5
August 2014FairVery GoodVery GoodFair3072.5
August 2013FairVery GoodVery GoodFair3072.5
August 2012FairFairSatisfactorySatisfactory3036.3
August 2011FairFairSatisfactorySatisfactory3036.3
August 2010FairFairSatisfactorySatisfactory3036.3
February 2010FairFairSatisfactorySatisfactory3036.3
September 2008FairFairSatisfactorySatisfactory3068.0
October 2006FairSatisfactorySatisfactorySatisfactory3069.0
October 2004FairSatisfactorySatisfactorySatisfactory2567.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.249249000
Steel Protective Coatingsq. ft.125125000
Deck
Reinforced Concrete Decksq. ft.449445400
Substructure
Reinforced Concrete Pier Walllinear ft.1818000
Reinforced Concrete Abutmentlinear ft.4242000
Reinforced Concrete Pile Cap/Footinglinear ft.5400540