KY-323 over MIDDLE PITMAN CREEK
Map
Coordinates:
+37.35917, -85.4069437°21'33" N, 85°24'25" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-323 over MIDDLE PITMAN CREEK |
Structure number: | 109B00032N |
Old structure number: | 109*0323*B0032 (from 1992 edition) |
Location: | .55 MI N.W. OF JCT KY 883 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 40.0 ft. [12.2 m] |
Total length: | 128.9 ft. [39.3 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 24.0 ft. [7.3 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1953 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 513 [as of 2017] |
Truck traffic: | 11% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 67.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Satisfactory | Satisfactory | Good | 513 | 67.5 |
March 2016 | Fair | Satisfactory | Satisfactory | Good | 454 | 63.4 |
March 2014 | Fair | Satisfactory | Satisfactory | Good | 545 | 63.4 |
March 2012 | Fair | Satisfactory | Satisfactory | Good | 540 | 63.4 |
March 2010 | Fair | Good | Satisfactory | Good | 648 | 65.2 |
March 2008 | Fair | Fair | Satisfactory | Good | 583 | 64.3 |
March 2006 | Fair | Fair | Satisfactory | Good | 514 | 64.4 |
March 2004 | Fair | Satisfactory | Good | Good | 740 | 65.0 |
March 2000 | Fair | Satisfactory | Good | Good | 740 | 63.9 |
March 1998 | Fair | Satisfactory | Good | Good | 740 | 63.9 |
March 1996 | Fair | Satisfactory | Good | Good | 740 | 63.9 |
March 1994 | Fair | Satisfactory | Good | Good | 452 | 68.1 |
March 1992 | Fair | Satisfactory | Good | Good | 452 | 65.1 |
March 1990 | Fair | Satisfactory | Good | Good | 452 | 65.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 540 | 498 | 42 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 3,088 | 2,563 | 525 | 0 | 0 |
Wearing Surfaces | sq. ft. | 2,840 | 2,840 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 6 | 6 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 64 | 64 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 64 | 50 | 10 | 4 | 0 |
Joints |
Pourable Joint | linear ft. | 64 | 0 | 64 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 270 | 0 | 262 | 8 | 0 |