Share:

KY-139 over FK OF SCOTT BRANCH

Map

Coordinates:
+36.65472, -87.81583
36°39'17" N, 87°48'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-139 over FK OF SCOTT BRANCH
Structure number:111B00013N
Old structure number:111*0139*B0013 (from 1992 edition)
Location:1.5 MI N- TENN STATE LINE
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:7.9 ft. [2.4 m]
Total length:33.1 ft. [10.1 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1932
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:582 [as of 2015]
Truck traffic:12% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:80.6

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
June 2018Fair5 out of 1058280.6
June 2016Fair5 out of 1058280.6
June 2014Fair5 out of 1048481.1
June 2012Fair5 out of 1044881.3
June 2010Fair5 out of 1045381.2
June 2008Fair5 out of 1043281.3
July 2006Fair6 out of 1039594.8
June 2004Fair6 out of 1041594.7
June 2000Good7 out of 1039994.8
June 1998Good7 out of 1039994.8
June 1996Good7 out of 1037894.9
June 1994Good7 out of 1043791.7
June 1992Good7 out of 1043791.7
June 1990Good7 out of 1043791.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pile Cap/Footinglinear ft.1401400
Culvert
Reinforced Concrete Culvertlinear ft.110001100