Share:

KY-776 over SINKING CREEK

Map

Coordinates:
+36.83139, -84.69639
36°49'53" N, 84°41'47" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-776 over SINKING CREEK
Structure number:116B00019N
Old structure number:116*0776*B0019 (from 1992 edition)
Location:BETWEEN JCTS KY 790 N&S
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:29.9 ft. [9.1 m]
Total length:99.1 ft. [30.2 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:State Highway Agency [01]
Year built:1955
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:647 [as of 2015]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:81.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairSatisfactorySatisfactoryGood64781.3
May 2015FairGoodSatisfactoryGood65281.3
May 2013FairGoodSatisfactoryGood70781.3
May 2011GoodGoodGoodGood72181.3
May 2009GoodGoodGoodGood71281.3
May 2007GoodGoodGoodGood74581.3
May 2005GoodGoodGoodGood75081.3
May 2003GoodGoodGoodGood66581.3
May 2001GoodGoodGoodGood66581.3
May 1999GoodGoodGoodGood66581.3
May 1997GoodGoodGoodGood66580.3
May 1995GoodGoodGoodGood43678.9
May 1993GoodGoodGoodGood43674.4
May 1991GoodGoodGoodGood43674.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.3963563640
Deck
Reinforced Concrete Top Flangesq. ft.2,3732,083280100
Wearing Surfacessq. ft.2,1832,051122100
Substructure
Reinforced Concrete Columneach40400
Reinforced Concrete Abutmentlinear ft.4838730
Reinforced Concrete Pier Caplinear ft.52202930
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.198192600