TUCKER HOLLOW ROAD over DENNY CREEK
Map
Coordinates:
+36.81278, -84.6786136°48'46" N, 84°40'43" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | TUCKER HOLLOW ROAD over DENNY CREEK |
Structure number: | 116C00051N |
Location: | .8 MI S JCT KY 776 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 28.9 ft. [8.8 m] |
Total length: | 32.2 ft. [9.8 m] |
Roadway width between curbs: | 22.6 ft. [6.9 m] |
Deck width edge-to-edge: | 24.6 ft. [7.5 m] |
Skew angle: | 15° |
Owner: | County Highway Agency [02] |
Year built: | 1994 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 50 [as of 2009] |
Truck traffic: | 7% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 91.6 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Good | Good | Satisfactory | 50 | 91.6 |
March 2015 | Fair | Good | Good | Satisfactory | 50 | 91.6 |
March 2013 | Good | Good | Good | Good | 50 | 91.6 |
March 2011 | Good | Good | Good | Good | 50 | 91.6 |
March 2009 | Good | Good | Good | Very Good | 50 | 91.6 |
March 2007 | Good | Good | Good | Very Good | 40 | 91.7 |
March 2005 | Good | Good | Good | Very Good | 30 | 91.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 192 | 192 | 0 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 791 | 751 | 40 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 96 | 84 | 12 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 16 | 16 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 55 | 47 | 0 | 0 | 8 |
Steel Protective Coating | sq. ft. | 275 | 0 | 275 | 0 | 0 |