KY-270 over CRAB ORCHARD CREEK
Map
Coordinates:
+37.46222, -87.7794437°27'44" N, 87°46'46" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-270 over CRAB ORCHARD CREEK |
Structure number: | 117B00050N |
Old structure number: | 117*0270*B0050 (from 1992 edition) |
Location: | 2.5 MI S.E. OF JCT KY 132 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 80.1 ft. [24.4 m] |
Total length: | 83.0 ft. [25.3 m] |
Roadway width between curbs: | 18.0 ft. [5.5 m] |
Deck width edge-to-edge: | 20.0 ft. [6.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1922 |
Year reconstructed: | 1955 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Aluminum [7] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 206 [as of 2017] |
Truck traffic: | 11% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 48.7 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $287,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Good | Fair | Good | 206 | 48.7 |
November 2016 | Fair | Good | Fair | Good | 295 | 48.5 |
November 2014 | Fair | Good | Fair | Good | 259 | 48.6 |
November 2012 | Fair | Good | Fair | Good | 295 | 48.5 |
November 2010 | Fair | Very Good | Fair | Good | 199 | 48.7 |
July 2009 | Fair | Excellent | Fair | Good | 181 | 44.4 |
November 2008 | Fair | Satisfactory | Fair | Good | 220 | 44.4 |
December 2006 | Fair | Satisfactory | Fair | Good | 253 | 48.9 |
November 2004 | Fair | Satisfactory | Fair | Good | 295 | 48.9 |
November 2002 | Fair | Satisfactory | Fair | Good | 267 | 48.7 |
November 2000 | Fair | Satisfactory | Satisfactory | Good | 267 | 50.7 |
November 1998 | Fair | Satisfactory | Satisfactory | Good | 267 | 50.7 |
September 1997 | Fair | Satisfactory | Satisfactory | Good | 267 | 50.7 |
August 1997 | Fair | Satisfactory | Satisfactory | Good | 271 | 50.7 |
November 1996 | Fair | Satisfactory | Satisfactory | Good | 271 | 50.7 |
November 1994 | Fair | Satisfactory | Fair | Good | 129 | 47.2 |
November 1992 | Fair | Satisfactory | Satisfactory | Good | 129 | 57.2 |
November 1990 | Fair | Satisfactory | Satisfactory | Good | 129 | 57.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 800 | 404 | 200 | 196 | 0 |
Steel Protective Coating | sq. ft. | 2,500 | 2,500 | 0 | 0 | 0 |
Steel Truss | linear ft. | 160 | 14 | 126 | 20 | 0 |
Steel Protective Coating | sq. ft. | 5,000 | 4,000 | 0 | 1,000 | 0 |
Steel Floor Beam | linear ft. | 140 | 0 | 120 | 20 | 0 |
Steel Protective Coating | sq. ft. | 2,300 | 2,300 | 0 | 0 | 0 |
Steel Gusset Plate | each | 10 | 5 | 5 | 0 | 0 |
Steel Protective Coating | sq. ft. | 200 | 200 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 56 | 56 | 0 | 0 | 0 |
Deck |
Corrugated or Orthotropic Deck | sq. ft. | 1,680 | 1,680 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,499 | 1,381 | 0 | 108 | 10 |
Steel Protective Coating | sq. ft. | 1 | 1 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 6 | 4 | 2 | 0 | 0 |
Fixed Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 6 | 4 | 2 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 166 | 0 | 166 | 0 | 0 |
Steel Protective Coating | sq. ft. | 664 | 664 | 0 | 0 | 0 |