Share:

LOCAL ROAD over DRAINAGE DITCH

Map

Coordinates:
+29.98833, -90.04500
29°59'18" N, 90°02'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LOCAL ROAD over DRAINAGE DITCH
Structure number:023629593900271
Location:0.0 MI.N.OF FLORIDA
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:29.9 ft. [9.1 m]
Total length:29.9 ft. [9.1 m]
Roadway width between curbs:24.3 ft. [7.4 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:22.0 tons [20.0 metric tons]
Inventory rating:16.0 tons [14.5 metric tons]
Sufficiency rating:43.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$138,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
January 201743.4PoorPoorPoorPoorSD-
January 201543.2PoorPoorPoorPoorSD-
January 201343.2PoorPoorPoorPoorSD-
February 201143.2PoorPoorPoorPoorSD-
March 200943.2PoorPoorPoorPoorSD-
January 200743.2PoorPoorPoorPoorSD-
April 200543.2PoorPoorPoorPoorSD-
November 200343.2PoorPoorPoorPoorSD-
February 200243.2PoorPoorPoorPoorSD-
October 199943.2PoorPoorPoorPoorSD-
August 199761.2FairFairFairFair--
June 199561.2FairFairFairSatisfactory--
June 199371.2FairFairSatisfactorySatisfactory--
June 199166.2PoorPoorSatisfactorySatisfactorySD-

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.270160100100
Deck
Reinforced Concrete Decksq. ft.840084000
Substructure
Reinforced Concrete Abutmentlinear ft.1206840120
Joints
Strip Seal Jointlinear ft.60100500
Bearings
Fixed Bearingeach1801800
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.6000060