Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LA0182 over VERMILION R (PINHOOK RD)
Structure number:032800040103171
Location:.5 MI NORTH OF 3095
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:55.1 ft. [16.8 m]
Total length:264.1 ft. [80.5 m]
Roadway width between curbs:53.2 ft. [16.2 m]
Deck width edge-to-edge:63.7 ft. [19.4 m]
Vertical clearance above deck:21.0 ft. [6.4 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1981
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Movable - Lift [15]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:43,100 [as of 2016]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:67.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018FairSatisfactorySatisfactorySatisfactory4310067.4
September 2016FairSatisfactoryFairSatisfactory4370054.8
September 2014GoodGoodGoodGood4770066.6
October 2012GoodGoodGoodGood4810069.5
October 2010GoodGoodGoodGood5120069.0
December 2008GoodGoodGoodGood5100069.0
December 2006GoodGoodGoodGood5130069.0
December 2004GoodGoodGoodGood5040069.1
November 2002GoodGoodGoodGood5110069.0
December 2000GoodGoodGoodGood5069869.1
December 1998GoodGoodGoodGood4859069.5
December 1996GoodGoodGoodGood4859069.5
November 1994GoodGoodGoodGood4766669.1
December 1992GoodVery GoodGoodVery Good5169668.3
October 1990GoodVery GoodGoodVery Good5169668.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.7707462400
Steel Protective Coatingsq. ft.5,18205,158024
Prestressed Concrete Girder/Beamlinear ft.1,2301,230000
Deck
Reinforced Concrete Decksq. ft.13,4673,04010,42520
Superstructure
Steel Floor Beamlinear ft.1496371060
Steel Protective Coatingsq. ft.2,73094268201,106
Substructure
Reinforced Concrete Abutmentlinear ft.20815243130
Prestressed Concrete Pileeach67130540
Reinforced Concrete Pier Caplinear ft.3142664800
Joints
Compression Jointlinear ft.26519202449
Open Jointlinear ft.106106000
Bearings
Elastomeric Bearingeach6006000
Fixed Bearingeach40400
Steel Protective Coatingsq. ft.95004
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.440440000
Steel Protective Coatingsq. ft.1,5021,502000
Steel Protective Coatingsq. ft.1,1201,0645600