US0090 over ATCHAFALAYA RIVER
Map
Coordinates:
+29.69446, -91.2169029°41'40" N, 91°13'01" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US0090 over ATCHAFALAYA RIVER |
Structure number: | 035104240532701 |
Location: | INT OF US 90 AND LA 70 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 617.2 ft. [188.1 m] |
Total length: | 1839.0 ft. [560.5 m] |
Roadway width between curbs: | 67.9 ft. [20.7 m] |
Deck width edge-to-edge: | 79.1 ft. [24.1 m] |
Vertical clearance below bridge: | 49.2 ft. [15.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1975 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: March 2016
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 33,800 [as of 2014] |
Truck traffic: | 12% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 49.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $12,192,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2016 | Poor | Good | Serious | Satisfactory | 33800 | 49.4 |
March 2015 | Poor | Good | Serious | Satisfactory | 34200 | 49.4 |
March 2014 | Poor | Good | Serious | Satisfactory | 33800 | 49.4 |
March 2012 | Poor | Good | Serious | Satisfactory | 33000 | 47.0 |
March 2010 | Fair | Good | Satisfactory | Satisfactory | 32500 | 89.7 |
February 2008 | Fair | Good | Satisfactory | Satisfactory | 33900 | 89.5 |
March 2006 | Fair | Good | Satisfactory | Good | 31800 | 89.7 |
March 2004 | Fair | Good | Satisfactory | Good | 27500 | 90.1 |
February 2002 | Fair | Good | Satisfactory | Good | 25215 | 90.4 |
February 2000 | Fair | Good | Satisfactory | Good | 25187 | 88.4 |
February 1998 | Fair | Good | Satisfactory | Good | 25187 | 88.4 |
February 1996 | Fair | Good | Satisfactory | Good | 24767 | 88.9 |
March 1994 | Fair | Good | Satisfactory | Good | 24522 | 91.2 |
January 1992 | Fair | Good | Satisfactory | Good | 22166 | 91.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 18,460 | 4,874 | 13,550 | 36 | 0 |
Steel Protective Coating | sq. ft. | 170,755 | 0 | 0 | 170,755 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 132,912 | 0 | 132,912 | 0 | 0 |
Superstructure |
Steel Truss | linear ft. | 3,692 | 0 | 2,793 | 899 | 0 |
Steel Protective Coating | sq. ft. | 100 | 0 | 0 | 100 | 0 |
Steel Floor Beam | linear ft. | 3,626 | 0 | 3,586 | 40 | 0 |
Steel Protective Coating | sq. ft. | 65,359 | 0 | 0 | 65,359 | 0 |
Steel Pin or Pin & Hangar Assembly | each | 8 | 2 | 0 | 6 | 0 |
Steel Gusset Plate | each | 96 | 0 | 48 | 48 | 0 |
Steel Protective Coating | sq. ft. | 2,584 | 0 | 0 | 2,584 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 4 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 288 | 263 | 0 | 25 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 144 | 144 | 0 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 1,440 | 0 | 0 | 0 | 1,440 |
Assembly without Seal Joint | linear ft. | 298 | 188 | 40 | 70 | 0 |
Bearings |
Movable Bearing | each | 8 | 6 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 640 | 0 | 640 | 0 | 0 |
Enclosed/Concealed Bearing | each | 30 | 22 | 8 | 0 | 0 |
Steel Protective Coating | sq. ft. | 640 | 0 | 640 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 5,538 | 4,914 | 615 | 9 | 0 |