Share:

LA0511 over RED R.,C.FANT PKWY,AR TE

Map

Coordinates:
+32.45881, -93.68179
32°27'32" N, 93°40'54" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LA0511 over RED R.,C.FANT PKWY,AR TE
Structure number:040801020300001
Location:1.0 MI WEST OF US 71
Purpose:Carries highway over highway and waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:400.0 ft. [121.9 m]
Total length:2823.3 ft. [860.5 m]
Roadway width between curbs:30.2 ft. [9.2 m]
Deck width edge-to-edge:33.5 ft. [10.2 m]
Vertical clearance above deck:17.1 ft. [5.2 m]
Vertical clearance below bridge:81.0 ft. [24.7 m]
Owner:State Highway Agency [01]
Year built:1968
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:22,200 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Operating rating:77.8 tons [70.7 metric tons]
Inventory rating:38.0 tons [34.5 metric tons]
Sufficiency rating:36.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$11,008,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 201736.0PoorPoorPoorPoorSD22200
August 201536.0PoorPoorPoorPoorSD22200
July 201436.0PoorPoorPoorPoorSD21800
July 201336.0PoorPoorPoorPoorSD21400
November 201136.0PoorPoorPoorFairSD21300
November 201036.0PoorPoorPoorFairSD21000
December 200941.0PoorSatisfactoryPoorFairSD18600
December 200841.0PoorSatisfactoryFairPoorSD18600
December 200741.0PoorSatisfactoryFairPoorSD18600
November 200641.0PoorSatisfactoryFairPoorSD18700
December 200541.0PoorSatisfactoryFairPoorSD18700
November 200441.0PoorSatisfactoryFairPoorSD18700
December 200341.0PoorSatisfactoryFairPoorSD22500
December 200240.7PoorSatisfactoryFairPoorSD21900
December 200140.7PoorSatisfactoryFairPoorSD21874
December 200040.7PoorSatisfactoryFairPoorSD21874
December 199940.7PoorSatisfactoryFairPoorSD21874
April 199940.7PoorSatisfactoryFairPoorSD21874
December 199740.7PoorSatisfactoryFairPoorSD28664
December 199640.7PoorSatisfactorySatisfactoryPoorSD28951
November 199540.7PoorSatisfactorySatisfactoryPoorSD14947
December 199440.7PoorSatisfactorySatisfactoryPoorSD14799
December 199272.9FairSatisfactorySatisfactorySatisfactory-13105
December 199072.9FairSatisfactorySatisfactorySatisfactory-13105

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.4,4201,3203,10000
Steel Stringerlinear ft.8,1165,4322,4871970
Deck
Reinforced Concrete Decksq. ft.51,30051,300000
Superstructure
Steel Trusslinear ft.4,43201,1053,3270
Steel Floor Beamlinear ft.3,0447032,274670
Steel Pin or Pin & Hangar Assemblyeach125700
Substructure
Reinforced Concrete Pier Walllinear ft.3603600
Reinforced Concrete Abutmentlinear ft.140014000
Reinforced Concrete Pile Cap/Footinglinear ft.1010000
Reinforced Concrete Pileeach1331000
Reinforced Concrete Pier Caplinear ft.150015000
Joints
Strip Seal Jointlinear ft.6000600
Pourable Jointlinear ft.6006000
Open Jointlinear ft.420004200
Assembly without Seal Jointlinear ft.2106015000
Bearings
Movable Bearingeach1000100
Fixed Bearingeach3403400
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.6,09406,09400
Deck
Reinforced Concrete Slabsq. ft.33,24033,240000