Share:

EAST KINGS HWY over DRAIN - C-6

Map 

Coordinates:
+32.43826, -93.70581
32°26'18" N, 93°42'21" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:EAST KINGS HWY over DRAIN - C-6
Structure number:040932263934221
Location:0.1 M SOUTH OF LA 3132
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:47.9 ft. [14.6 m]
Roadway width between curbs:59.4 ft. [18.1 m]
Deck width edge-to-edge:122.4 ft. [37.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1990
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: April 2017 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,100 [as of 1979]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:43.9 tons [39.9 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:98.7

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
April 201798.7Fair6 out of 10-3100
April 201598.7Good7 out of 10-3100
April 201398.7Good7 out of 10-3100
April 201198.7Good7 out of 10-3100
March 200998.7Good7 out of 10-3100
April 200798.7Good7 out of 10-3100
March 200598.7Good7 out of 10-3100
March 200398.7Good8 out of 10-3100
February 200198.7Good8 out of 10-3100
March 199998.7Good8 out of 10-3100
February 199798.7Good8 out of 10-3100
January 199598.8Good8 out of 10-3100
March 199398.8Good8 out of 10-3100
April 199198.8Good8 out of 10-3100