Facts 

Name:MAYFIELD ROAD over HOLLYWOOD DITCH
Structure number:040932272934841
Location:0.2 MI EAST OF KENNEDY AV
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:30.8 ft. [9.4 m]
Roadway width between curbs:25.3 ft. [7.7 m]
Deck width edge-to-edge:51.8 ft. [15.8 m]
Owner:City or Municipal Highway Agency [04]
Year built:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: April 2017 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:280 [as of 1979]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.9 tons [40.8 metric tons]
Inventory rating:27.0 tons [24.5 metric tons]
Sufficiency rating:85.7

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
April 201785.7Fair6 out of 10-280
April 201583.5Fair6 out of 10-280
April 201382.0Fair6 out of 10-280
April 201182.0Fair6 out of 10-280
March 200981.0Fair6 out of 10-280
March 200781.0Fair6 out of 10-280
March 200581.0Fair6 out of 10-280
April 200381.0Fair6 out of 10-280
March 200181.0Fair6 out of 10-280
February 199981.0Fair6 out of 10-280
January 199781.0Fair6 out of 10-280
January 199581.0Fair6 out of 10-280
March 199381.0Fair6 out of 10-280
March 199181.0Good7 out of 10-280