Share:

FAIR ST over HUDSON STREET

Map

Coordinates:
+32.47510, -93.78861
32°28'30" N, 93°47'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAIR ST over HUDSON STREET
Structure number:040932285934731
Location:0.6 MI W OF LA171
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Local (Urban) [19]
Length of largest span:85.0 ft. [25.9 m]
Total length:86.9 ft. [26.5 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:37.1 ft. [11.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:19°
Owner:City or Municipal Highway Agency [04]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:200 [as of 1979]
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:76.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairFairSatisfactoryFair20076.0
April 2015FairSatisfactorySatisfactorySatisfactory20088.0
April 2013FairSatisfactorySatisfactorySatisfactory20088.0
April 2011FairSatisfactoryGoodGood20089.0
April 2009FairSatisfactoryGoodGood20089.0
March 2007FairSatisfactoryGoodGood20089.0
March 2005FairSatisfactoryGoodGood20089.0
April 2003FairSatisfactoryGoodGood20089.0
March 2001FairSatisfactoryGoodGood20089.0
February 1999FairSatisfactoryGoodGood20089.0
January 1997FairSatisfactoryGoodGood20089.0
January 1995FairSatisfactoryGoodGood20089.0
March 1993FairSatisfactoryGoodGood20089.0
April 1991GoodVery GoodVery GoodVery Good20089.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.609608010
Deck
Reinforced Concrete Decksq. ft.2,43602,43600
Substructure
Reinforced Concrete Columneach55000
Reinforced Concrete Abutmentlinear ft.120394770
Joints
Strip Seal Jointlinear ft.5600056
Bearings
Elastomeric Bearingeach149050
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.174174000
Steel Protective Coatingsq. ft.182182000
Reinforced Concrete Bridge Raillinear ft.174017400