Share:

STONER STREET over LINE AVE

Map

Coordinates:
+32.50000, -93.74670
32°30'00" N, 93°44'48" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:STONER STREET over LINE AVE
Structure number:040932300934481
Location:1.3 MI. WEST OF LA 1
Purpose:Carries highway over highway
Route classification:Local (Urban) [19]
Length of largest span:69.9 ft. [21.3 m]
Total length:380.9 ft. [116.1 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:49.5 ft. [15.1 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:10,120 [as of 1979]
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:36.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,683,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairFairSatisfactoryFair1012036.2
March 2015FairFairFairFair1012035.9
March 2013FairFairFairFair1012035.9
March 2011FairFairFairFair1012035.9
April 2009FairFairFairFair1012035.9
April 2007FairFairFairFair1012035.9
March 2005FairFairFairFair1012035.9
March 2003FairFairFairFair1012035.9
February 2001FairFairFairFair1012035.9
March 1999FairFairFairFair1012035.9
February 1997FairFairFairFair1012035.9
February 1995FairFairFairFair1012036.6
March 1993FairFairFairFair1012036.6
April 1991FairSatisfactoryFairSatisfactory1012037.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,3879251,46200
Steel Protective Coatingsq. ft.18,61518,29032500
Deck
Reinforced Concrete Decksq. ft.13,600012,7928080
Substructure
Reinforced Concrete Columneach1811430
Reinforced Concrete Abutmentlinear ft.110951500
Reinforced Concrete Pier Caplinear ft.30827424100
Joints
Pourable Jointlinear ft.8408400
Assembly without Seal Jointlinear ft.336033600
Bearings
Movable Bearingeach9809800
Steel Protective Coatingsq. ft.259025900
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.840840000
Steel Protective Coatingsq. ft.1,0961,096000
Reinforced Concrete Bridge Raillinear ft.840840000
Deck
Reinforced Concrete Slabsq. ft.1,68001,68000