Share:

MONTANA ST over COOPER ROAD DITCH

Map

Coordinates:
+32.54993, -93.80118
32°32'60" N, 93°48'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MONTANA ST over COOPER ROAD DITCH
Structure number:040932330934811
Location:0.2 M N OF LA3194
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:19.0 ft. [5.8 m]
Total length:59.1 ft. [18.0 m]
Roadway width between curbs:28.2 ft. [8.6 m]
Deck width edge-to-edge:30.8 ft. [9.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1982
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:650 [as of 1979]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:75.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairSatisfactorySatisfactoryFair65075.7
April 2015FairGoodGoodFair65075.4
April 2013FairGoodGoodSatisfactory65087.4
April 2011FairGoodGoodSatisfactory65089.4
August 2010FairGoodGoodSatisfactory65089.4
March 2009FairGoodGoodSatisfactory65089.4
March 2007FairGoodGoodSatisfactory65089.4
March 2005FairGoodGoodSatisfactory65089.4
March 2003FairGoodGoodSatisfactory65089.4
March 2001FairGoodGoodSatisfactory65089.4
February 1999FairGoodGoodSatisfactory65089.4
January 1997FairGoodGoodSatisfactory65089.4
January 1995FairGoodGoodSatisfactory65089.4
March 1993FairGoodGoodSatisfactory65089.4
April 1991GoodVery GoodVery GoodGood65089.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Timber Abutmentlinear ft.9209020
Timber Pileeach2017300
Reinforced Concrete Pier Caplinear ft.1361261000
Joints
Pourable Jointlinear ft.136001360
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1770591180
Steel Protective Coatingsq. ft.747747000
Deck
Reinforced Concrete Slabsq. ft.1,7981,796200
Wearing Surfacessq. ft.1,6521,30434800