Facts 

Name:LOCAL ROAD over JONES CREEK
Structure number:611730279910532
Location:BATON ROUGE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Rural) [09]
Length of largest span:20.0 ft. [6.1 m]
Total length:113.9 ft. [34.7 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:County Highway Agency [02]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:6
Main spans material:Wood or timber [7]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: February 2016 

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:5,446 [as of 1979]
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:40.6 tons [36.9 metric tons]
Inventory rating:29.7 tons [27.0 metric tons]
Sufficiency rating:48.7
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$390,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201648.7PoorGoodFairPoorSD5446
February 201448.7PoorGoodFairPoorSD5446
March 201215.8PoorGoodFairCriticalSD5446
April 201048.7PoorGoodSatisfactoryPoorSD5446
April 200862.1FairGoodSatisfactoryFairFO5446
May 200673.2FairGoodGoodSatisfactoryFO5446
March 200473.2FairGoodGoodSatisfactoryFO5446
April 200273.2FairVery GoodVery GoodSatisfactoryFO5446
May 200073.2FairVery GoodVery GoodSatisfactoryFO5446
May 199876.2FairVery GoodVery GoodSatisfactoryFO5446
May 199676.2GoodGoodGoodGoodFO5446
December 199376.4GoodGoodGoodGoodFO5446
January 199276.4GoodGoodGoodGoodFO5446