Share:

I 295 NB over I 95

Map

Coordinates:
+41.95515, -71.30429
41°57'19" N, 71°18'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 295 NB over I 95
Structure number:A160613UFDOTNBI
Old structure number:098602003101 (from 1992 edition)
Location:I-295 AT I-95
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:112.9 ft. [34.4 m]
Total length:301.9 ft. [92.0 m]
Roadway width between curbs:52.2 ft. [15.9 m]
Deck width edge-to-edge:58.1 ft. [17.7 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:34°
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:19,700 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:90.3
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$854,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairSatisfactoryGoodGood1970090.3
November 2015FairSatisfactoryGoodGood2160089.8
November 2013FairSatisfactoryGoodGood2160089.8
November 2011FairSatisfactoryGoodGood2160089.8
November 2009FairSatisfactoryFairFair2160078.0
July 1995GoodGoodGoodGood400075.7
July 1993GoodGoodGoodGood1510071.8
July 1991GoodGoodGoodGood1489675.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,4232,423000
Steel Protective Coatingsq. ft.20,59620,596000
Deck
Reinforced Concrete Decksq. ft.17,57716,5414026340
Wearing Surfacessq. ft.15,70512,9207852,0000
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.146146000
Reinforced Concrete Pier Caplinear ft.132132000
Joints
Other Jointlinear ft.126001260
Bearings
Movable Bearingeach2424000
Steel Protective Coatingsq. ft.8888000
Fixed Bearingeach2424000
Steel Protective Coatingsq. ft.9696000
Bridge Rail
Other Material Bridge Raillinear ft.604604000