Share:

ST 28 CHAS R DM RD over WATER CHARLES RIVER

Map

Coordinates:
+42.36861, -71.07186
42°22'07" N, 71°04'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ST 28 CHAS R DM RD over WATER CHARLES RIVER
Structure number:B160134ETDOTNBI
Old structure number:MDC896040101 (from 1992 edition)
Location:.2 MI NW OF NASHUA ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:18.0 ft. [5.5 m]
Total length:116.1 ft. [35.4 m]
Roadway width between curbs:65.0 ft. [19.8 m]
Deck width edge-to-edge:86.0 ft. [26.2 m]
Owner:State Highway Agency [01]
Year built:1906
Year reconstructed:2011
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Number of main spans:10
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:58,400 [as of 2016]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:39.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018PoorSatisfactoryFairPoor5840039.0
February 2016PoorSatisfactoryFairPoor5840039.0
February 2014PoorSatisfactoryFairPoor4400039.9
February 2012PoorSatisfactoryFairPoor5200038.5
February 2010PoorSatisfactoryPoorSerious4950021.5
February 2000FairSatisfactorySatisfactorySatisfactory4950068.5
February 1996FairGoodSatisfactoryFair5430454.4
February 1994PoorSatisfactorySatisfactoryPoor4614739.0
February 1992PoorSatisfactorySatisfactoryPoor4700039.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,0081,3395491200
Deck
Reinforced Concrete Decksq. ft.7,9127,55535700
Wearing Surfacessq. ft.6,1926,187500
Substructure
Steel Columneach2215700
Steel Protective Coatingsq. ft.783783000
Reinforced Concrete Pier Walllinear ft.1611305260
Reinforced Concrete Abutmentlinear ft.2692369240
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.232224350