Share:

I 93 RAMP KK over OTHER RELIEF

Map

Coordinates:
+42.34750, -71.05944
42°20'51" N, 71°03'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 93 RAMP KK over OTHER RELIEF
Structure number:B165069RRDOTNBI
Location:.8 KM N OF I90
Route classification:Collector (Urban) [17]
Length of largest span:24.0 ft. [7.3 m]
Total length:76.4 ft. [23.3 m]
Roadway width between curbs:29.5 ft. [9.0 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Owner:State Highway Agency [01]
Year built:2003
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Other [00]
Deck type:Other [9]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:19,784 [as of 2015]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:99.4 tons [90.4 metric tons]
Inventory rating:59.8 tons [54.4 metric tons]
Sufficiency rating:97.2
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$266,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201597.2FairSatisfactoryGoodSatisfactory-19784
December 201397.7FairSatisfactoryGoodSatisfactory-16400
December 201198.4FairSatisfactoryGoodSatisfactory-11500
December 200998.4FairSatisfactoryGoodSatisfactory-11500

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2362181800
Deck
Reinforced Concrete Decksq. ft.2,2572,2273000
Wearing Surfacessq. ft.2,2572,257000
Superstructure
Prestressed Concrete Floor Beamlinear ft.5959000
Substructure
Reinforced Concrete Columneach1211100
Joints
Compression Jointlinear ft.118118000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1531282500