Share:

I 93 SB over OTHER RELIEF

Map

Coordinates:
+42.34694, -71.06028
42°20'49" N, 71°03'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 93 SB over OTHER RELIEF
Structure number:B165099RPDOTNBI
Location:I93
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:64.0 ft. [19.5 m]
Total length:202.8 ft. [61.8 m]
Roadway width between curbs:59.4 ft. [18.1 m]
Deck width edge-to-edge:63.3 ft. [19.3 m]
Owner:State Highway Agency [01]
Year built:2000
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: March 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:84,100 [as of 2009]
Truck traffic:7% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:75.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$4,322,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201575.7FairGoodFairGood-84100
March 201375.7FairGoodFairGood-84100
March 201175.7FairGoodFairGood-84100
March 200975.7FairGoodFairGood-84100

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,7911,71566100
Deck
Reinforced Concrete Decksq. ft.12,88012,880000
Wearing Surfacessq. ft.12,88012,880000
Substructure
Steel Columneach3603600
Steel Protective Coatingsq. ft.999999000
Reinforced Concrete Pier Walllinear ft.6059100
Reinforced Concrete Abutmentlinear ft.7976300
Reinforced Concrete Pier Caplinear ft.126126000
Joints
Strip Seal Jointlinear ft.7007000
Assembly with Sealeach6060000
Bearings
Elastomeric Bearingeach5451300
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3983386000