HWY ADAMSVLLE RD over WATER NORTH RIVER
Map
Coordinates:
+42.65821, -72.7149442°39'30" N, 72°42'54" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | HWY ADAMSVLLE RD over WATER NORTH RIVER |
Structure number: | C180080EYMUNNBI |
Old structure number: | 0EYMUN210053100 (from 1992 edition) |
Location: | INT. 112 & ADAMSVILLE RD |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 119.8 ft. [36.5 m] |
Total length: | 125.3 ft. [38.2 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 35.8 ft. [10.9 m] |
Vertical clearance above deck: | 15.1 ft. [4.6 m] |
Owner: | Town or Township Highway Agency [03] |
Year built: | 1937 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Steel [3] |
Main span design: | Arch - Thru [12] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 780 [as of 2013] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 52.1 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $2,203,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Satisfactory | Fair | Satisfactory | 780 | 52.1 |
August 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 780 | 63.2 |
September 2013 | Fair | Satisfactory | Satisfactory | Good | 780 | 63.2 |
September 2011 | Fair | Satisfactory | Good | Good | 570 | 69.2 |
September 2009 | Fair | Satisfactory | Good | Good | 570 | 69.2 |
September 2007 | Fair | Satisfactory | Good | Good | 200 | 71.4 |
August 2005 | Fair | Satisfactory | Good | Good | 200 | 72.4 |
August 2003 | Fair | Satisfactory | Good | Good | 200 | 73.4 |
August 2001 | Fair | Satisfactory | Good | Good | 200 | 73.4 |
August 1999 | Fair | Satisfactory | Good | Good | 200 | 71.4 |
August 1997 | Fair | Satisfactory | Good | Good | 200 | 71.4 |
August 1995 | Fair | Satisfactory | Good | Good | 200 | 71.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Deck |
Reinforced Concrete Deck | sq. ft. | 4,500 | 3,850 | 200 | 450 | 0 |
Wearing Surfaces | sq. ft. | 3,000 | 0 | 0 | 750 | 2,250 |
Superstructure |
Steel Arch | linear ft. | 250 | 0 | 250 | 0 | 0 |
Steel Protective Coating | sq. ft. | 3,420 | 0 | 1,710 | 0 | 1,710 |
Steel Floor Beam | linear ft. | 335 | 0 | 279 | 56 | 0 |
Steel Protective Coating | sq. ft. | 2,718 | 0 | 1,100 | 0 | 1,618 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 97 | 0 | 48 | 49 | 0 |
Joints |
Open Joint | linear ft. | 27 | 0 | 0 | 27 | 0 |
Bearings |
Fixed Bearing | each | 4 | 0 | 4 | 0 | 0 |
Steel Protective Coating | sq. ft. | 32 | 0 | 16 | 0 | 16 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 250 | 0 | 247 | 3 | 0 |
Steel Protective Coating | sq. ft. | 625 | 0 | 300 | 0 | 325 |