Share:

HWY ALMOND ST over RR (ABANDONED)

Map

Coordinates:
+41.69920, -71.17043
41°41'57" N, 71°10'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:HWY ALMOND ST over RR (ABANDONED)
Structure number:F0200840BDOT634
Location:.1 MI N OF WILLIAM ST
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:43.3 ft. [13.2 m]
Total length:49.2 ft. [15.0 m]
Roadway width between curbs:26.2 ft. [8.0 m]
Deck width edge-to-edge:41.7 ft. [12.7 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:24°
Owner:State Highway Agency [01]
Year built:1897
Year reconstructed:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:3,900 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:76.5
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$1,076,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018GoodGoodVery GoodGood390076.5
February 2016GoodGoodVery GoodGood390076.5
February 2014GoodGoodVery GoodGood740076.1
February 2012GoodGoodVery GoodVery Good740076.1
February 2010GoodGoodVery GoodVery Good740076.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.157157000
Steel Protective Coatingsq. ft.753753000
Deck
Reinforced Concrete Decksq. ft.1,5921,5326000
Superstructure
Steel Floor Beamlinear ft.441441000
Steel Protective Coatingsq. ft.2,1192,119000
Substructure
Masonry Abutmentlinear ft.194194000
Bearings
Elastomeric Bearingeach1616000
Movable Bearingeach88000
Steel Protective Coatingsq. ft.3232000
Fixed Bearingeach88000
Steel Protective Coatingsq. ft.3232000