ST 79 over HWY RAMP B
Map
Coordinates:
+41.71960, -71.1536641°43'11" N, 71°09'13" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ST 79 over HWY RAMP B |
Structure number: | F020893V8DOTNBI |
Old structure number: | 3V8103615012101 (from 1992 edition) |
Location: | .2 MI S OF US 6 |
Purpose: | Carries highway over highway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 99.1 ft. [30.2 m] |
Total length: | 102.0 ft. [31.1 m] |
Roadway width between curbs: | 119.1 ft. [36.3 m] |
Deck width edge-to-edge: | 155.8 ft. [47.5 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 15° |
Owner: | State Highway Agency [01] |
Year built: | 1973 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 25,000 [as of 2015] |
Truck traffic: | 10% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 94.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $7,874,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Good | Satisfactory | Satisfactory | 25000 | 94.4 |
August 2015 | Fair | Good | Satisfactory | Satisfactory | 25000 | 95.4 |
August 2013 | Fair | Good | Satisfactory | Satisfactory | 25000 | 95.4 |
August 2011 | Fair | Good | Satisfactory | Satisfactory | 25000 | 95.4 |
August 2009 | Fair | Good | Fair | Satisfactory | 25000 | 85.0 |
August 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 19000 | 97.0 |
August 1997 | Good | Good | Good | Good | 19000 | 96.0 |
September 1995 | Good | Good | Good | Good | 19000 | 85.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,987 | 1,657 | 330 | 0 | 0 |
Steel Protective Coating | sq. ft. | 27,620 | 0 | 11,772 | 8,359 | 7,489 |
Deck |
Reinforced Concrete Deck | sq. ft. | 15,159 | 15,016 | 143 | 0 | 0 |
Wearing Surfaces | sq. ft. | 14,136 | 12,506 | 700 | 930 | 0 |
Concrete Protective Coating | sq. ft. | 14,136 | 0 | 12,256 | 1,600 | 280 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 323 | 73 | 191 | 59 | 0 |
Joints |
Compression Joint | linear ft. | 169 | 65 | 29 | 45 | 30 |
Bearings |
Movable Bearing | each | 21 | 17 | 4 | 0 | 0 |
Steel Protective Coating | sq. ft. | 42 | 0 | 22 | 20 | 0 |
Fixed Bearing | each | 21 | 9 | 12 | 0 | 0 |
Steel Protective Coating | sq. ft. | 42 | 0 | 0 | 18 | 24 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 186 | 186 | 0 | 0 | 0 |
Other Material Bridge Rail | linear ft. | 192 | 137 | 55 | 0 | 0 |