Share:

HWY WATER ST over WATER EEL POND

Map

Coordinates:
+41.52430, -70.67028
41°31'27" N, 70°40'13" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:HWY WATER ST over WATER EEL POND
Structure number:F0300543EMUNNBI
Old structure number:TWN714003100 (from 1992 edition)
Location:3.2 MI SW OF RT 28-W.HOLE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:40.0 ft. [12.2 m]
Total length:55.8 ft. [17.0 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:40.0 ft. [12.2 m]
Vertical clearance below bridge:3.3 ft. [1.0 m]
Owner:Town or Township Highway Agency [03]
Year built:1940
Year reconstructed:2009
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Steel [3]
Main span design:Movable - Bascule [16]
Deck type:Closed Grating [4]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,020 [as of 2017]
Truck traffic:12% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:73.6
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$1,367,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017FairGoodGoodSatisfactory302073.6
July 2015FairGoodGoodSatisfactory427574.5
July 2013FairGoodGoodSatisfactory427573.5
July 2011FairGoodVery GoodSatisfactory528073.4
July 2009FairVery GoodVery GoodSatisfactory528073.4
September 2007PoorSeriousSeriousSatisfactory52802.0
September 2005PoorSeriousSeriousSatisfactory52802.0
September 2003PoorSeriousSeriousSatisfactory52802.0
September 2001PoorSeriousSeriousSatisfactory43002.0
October 1999PoorSeriousPoorSatisfactory43002.0
September 1995PoorFairPoorGood580044.2
September 1993FairFairFairGood580056.2
August 1992PoorFairPoorGood184046.7
August 1990PoorFairPoorGood184046.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.124012400
Steel Protective Coatingsq. ft.1,8651,8155000
Steel Stringerlinear ft.161016100
Steel Protective Coatingsq. ft.1,1051,0753000
Deck
Reinforced Concrete Decksq. ft.508508000
Superstructure
Steel Floor Beamlinear ft.1311112000
Steel Protective Coatingsq. ft.1,4791,4394000
Substructure
Reinforced Concrete Abutmentlinear ft.9038700
Deck
Concrete Filled Grid Decksq. ft.770770000
Steel Protective Coatingsq. ft.770770000
Joints
Open Jointlinear ft.4949000
Bearings
Movable Bearingeach22000
Steel Protective Coatingsq. ft.33000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7975400
Steel Protective Coatingsq. ft.378373500