I 495 RAMP B over WATER CANOE RIVER
Map
Coordinates:
+41.98161, -71.1610541°58'54" N, 71°09'40" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I 495 RAMP B over WATER CANOE RIVER |
Structure number: | N230373RQDOTNBI |
Old structure number: | 3RQ096628009101 (from 1992 edition) |
Location: | I-495 SB RAMP TO 123 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 44.0 ft. [13.4 m] |
Total length: | 47.9 ft. [14.6 m] |
Roadway width between curbs: | 23.0 ft. [7.0 m] |
Deck width edge-to-edge: | 25.9 ft. [7.9 m] |
Skew angle: | 3° |
Owner: | State Highway Agency [01] |
Year built: | 1978 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 3,900 [as of 2015] |
Truck traffic: | 12% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Superior to present desirable criteria [9] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 92.6 |
Recommended work: | Widening of existing bridge or other major structure without deck rehabilitation or replacement [33] |
Estimated cost of work: | $1,166,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 3900 | 92.6 |
April 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 3800 | 93.6 |
April 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 3800 | 93.6 |
April 2012 | Fair | Good | Good | Satisfactory | 3600 | 93.7 |
April 2010 | Fair | Good | Good | Satisfactory | 3600 | 93.7 |
April 2008 | Fair | Good | Good | Satisfactory | 3600 | 93.7 |
November 1998 | Fair | Very Good | Satisfactory | Good | 3000 | 93.7 |
January 1997 | Fair | Very Good | Satisfactory | Good | 3000 | 83.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 186 | 150 | 10 | 26 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,186 | 786 | 400 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,047 | 1,047 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 200 | 160 | 20 | 20 | 0 |
Joints |
Compression Joint | linear ft. | 46 | 45 | 0 | 0 | 1 |
Bearings |
Elastomeric Bearing | each | 8 | 8 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 200 | 0 | 100 | 100 | 0 |