Share:

HWY TULLY RD over WATER W BR TULLY RIVER

Map

Coordinates:
+42.66356, -72.26681
42°39'49" N, 72°16'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:HWY TULLY RD over WATER W BR TULLY RIVER
Structure number:O030050TXMUNNBI
Location:@BTTRWTH RD BLISSVILLE
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:26.9 ft. [8.2 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:33.1 ft. [10.1 m]
Skew angle:35°
Owner:Town or Township Highway Agency [03]
Year built:1951
Historic significance:Historical significance is not determinable at this time [4]
Main span material:Steel [3]
Main span design:Arch - Deck [11]
Deck type:Not applicable [N]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:776 [as of 2003]
Truck traffic:5% of total traffic
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:81.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,420,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2017Fair-GoodFair77681.8
January 2015Fair-GoodFair77681.8
January 2013Poor-GoodPoor77665.6
January 2011Poor-GoodPoor77665.6
January 2009Poor-GoodPoor77665.6
January 2007Poor-GoodPoor77665.6
January 2005Fair-GoodSatisfactory77692.8
January 2003Fair-GoodSatisfactory77692.8
January 2001Fair-GoodSatisfactory140081.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pile Cap/Footinglinear ft.8080000
Culvert
Steel Culvertlinear ft.2702700
Steel Protective Coatingsq. ft.6,6146,31430000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7575000
Steel Protective Coatingsq. ft.225225000