ST 7 A/ASHLEY FLS over WATER HOUSATONIC RIVER
Map
Coordinates:
+42.06959, -73.3401642°04'11" N, 73°20'25" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ST 7 A/ASHLEY FLS over WATER HOUSATONIC RIVER |
Structure number: | S100020D5DOTNBI |
Old structure number: | 854132016101 (from 1992 edition) |
Location: | 1.6 MI N OF CONN SL |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 98.4 ft. [30.0 m] |
Total length: | 105.0 ft. [32.0 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 27.9 ft. [8.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1925 |
Year reconstructed: | 1988 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Poor |
Status: | Bridge closed to all traffic [K] |
Average daily traffic: | 400 [as of 2005] |
Truck traffic: | 1% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 33.1 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $3,287,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Poor | Good | Poor | Fair | 400 | 33.1 |
June 2015 | Poor | Good | Poor | Fair | 400 | 33.1 |
June 2013 | Poor | Good | Poor | Fair | 400 | 33.1 |
June 2011 | Poor | Good | Poor | Fair | 400 | 35.1 |
June 2009 | Poor | Good | Poor | Fair | 400 | 49.4 |
July 1999 | Fair | Very Good | Fair | Good | 300 | 62.9 |
July 1995 | Fair | Very Good | Fair | Satisfactory | 700 | 65.2 |
June 1993 | Fair | Very Good | Fair | Satisfactory | 700 | 65.2 |
February 1991 | Fair | Very Good | Fair | Fair | 639 | 65.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Stringer | linear ft. | 925 | 3 | 679 | 80 | 163 |
Steel Protective Coating | sq. ft. | 999 | 999 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 2,928 | 2,430 | 498 | 0 | 0 |
Wearing Surfaces | sq. ft. | 2,928 | 2,430 | 498 | 0 | 0 |
Superstructure |
Steel Truss | linear ft. | 207 | 0 | 141 | 52 | 14 |
Steel Protective Coating | sq. ft. | 999 | 999 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 171 | 0 | 125 | 28 | 18 |
Steel Protective Coating | sq. ft. | 999 | 999 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 89 | 74 | 15 | 0 | 0 |
Masonry Abutment | linear ft. | 53 | 0 | 48 | 5 | 0 |
Bearings |
Movable Bearing | each | 11 | 0 | 11 | 0 | 0 |
Steel Protective Coating | sq. ft. | 999 | 999 | 0 | 0 | 0 |
Fixed Bearing | each | 11 | 0 | 6 | 0 | 5 |
Steel Protective Coating | sq. ft. | 999 | 999 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 210 | 0 | 126 | 42 | 42 |
Steel Protective Coating | sq. ft. | 999 | 999 | 0 | 0 | 0 |