Share:

US202 ST10/ELM SB over WATER WESTFIELD RIVER

Map

Coordinates:
+42.12861, -72.74667
42°07'43" N, 72°44'48" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US202 ST10/ELM SB over WATER WESTFIELD RIVER
Structure number:W250100V8DOTNBI
Old structure number:0V8020251034101 (from 1992 edition)
Location:JCT MEADOW ST.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:184.1 ft. [56.1 m]
Total length:376.0 ft. [114.6 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:43.3 ft. [13.2 m]
Vertical clearance above deck:14.8 ft. [4.5 m]
Owner:State Highway Agency [01]
Year built:1938
Year reconstructed:2011
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:22,200 [as of 2016]
Truck traffic:10% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:68.2

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 201668.2FairVery GoodGoodSatisfactory-22200
July 201466.1FairVery GoodGoodSatisfactory-33900
July 201266.1GoodVery GoodGoodGood-33900
January 20114.0PoorSeriousSeriousFairSD33900
January 20094.0PoorSeriousSeriousPoorSD33900
January 199942.5PoorPoorFairSatisfactorySD30000
December 199650.8PoorPoorSatisfactorySatisfactorySD29000
October 199045.5FairFairFairSatisfactory-9044

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Stringerlinear ft.3,3143,314000
Steel Protective Coatingsq. ft.1,9981,998000
Deck
Reinforced Concrete Decksq. ft.22,08522,085000
Wearing Surfacessq. ft.14,72514,725000
Superstructure
Steel Trusslinear ft.7356617310
Steel Protective Coatingsq. ft.1,9981,998000
Steel Floor Beamlinear ft.738738000
Steel Protective Coatingsq. ft.1,9981,998000
Substructure
Masonry Pier Walllinear ft.5605600
Masonry Abutmentlinear ft.112011200
Joints
Strip Seal Jointlinear ft.8080000
Bearings
Movable Bearingeach44000
Steel Protective Coatingsq. ft.999999000
Fixed Bearingeach22000
Steel Protective Coatingsq. ft.999999000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.2,2082,208000
Steel Protective Coatingsq. ft.999999000