MD 313 over CHOPTANK RIVER
Map
Coordinates:
+38.97672, -75.8015238°58'36" N, 75°48'05" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | MD 313 over CHOPTANK RIVER |
Structure number: | 100000050005010 |
Location: | 0.32 MILE NORTH OF MD 314 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 52.2 ft. [15.9 m] |
Total length: | 263.1 ft. [80.2 m] |
Roadway width between curbs: | 35.4 ft. [10.8 m] |
Deck width edge-to-edge: | 38.7 ft. [11.8 m] |
Skew angle: | 26° |
Owner: | State Highway Agency [01] |
Year built: | 1949 |
Year reconstructed: | 1987 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 5 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: January 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,160 [as of 2009] |
Truck traffic: | 8% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | None present but re-evaluation suggested [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 80.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
January 2018 | Fair | Satisfactory | Fair | Fair | 7160 | 80.7 |
January 2016 | Fair | Satisfactory | Fair | Fair | 7160 | 80.7 |
January 2014 | Fair | Satisfactory | Fair | Fair | 7160 | 80.7 |
January 2012 | Fair | Satisfactory | Fair | Fair | 7160 | 80.7 |
January 2010 | Fair | Satisfactory | Satisfactory | Fair | 7320 | 80.7 |
January 2008 | Fair | Satisfactory | Satisfactory | Fair | 9325 | 80.3 |
November 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 9325 | 91.6 |
November 2003 | Fair | Good | Good | Satisfactory | 9325 | 91.6 |
November 2001 | Fair | Good | Good | Satisfactory | 4975 | 91.2 |
April 2000 | Fair | Good | Good | Fair | 4975 | 80.1 |
April 1998 | Fair | Good | Good | Fair | 4975 | 80.1 |
April 1996 | Fair | Good | Good | Fair | 4700 | 80.1 |
April 1994 | Fair | Good | Satisfactory | Good | 4700 | 91.2 |
April 1992 | Fair | Very Good | Satisfactory | Satisfactory | 4700 | 91.2 |
March 1990 | Fair | Very Good | Satisfactory | Good | 4700 | 88.3 |