Share:

YALE AVENUE over MAIDENS CHOICE CREEK

Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:YALE AVENUE over MAIDENS CHOICE CREEK
Structure number:200000BC8034020
Location:0.2 MI S OF FREDERICK AVE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:13.1 ft. [4.0 m]
Total length:30.8 ft. [9.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1950
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,204 [as of 2016]
Truck traffic:5% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:None present but re-evaluation suggested [5]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:36.0 tons [32.7 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:97.7
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$43,000

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
May 201697.7Fair6 out of 10-1204
May 201497.7Fair6 out of 10-1100
May 201297.7Fair6 out of 10-1100
May 201086.7Fair5 out of 10-1100
November 200986.7Fair5 out of 10-1100
November 200786.7Fair5 out of 10-1100
September 200586.7Fair5 out of 10-1100
October 200396.7Fair6 out of 10-1100
September 200385.7Fair5 out of 10-1100
November 200196.8Fair6 out of 10-999
January 200096.8Fair6 out of 10-999
January 199896.8Fair6 out of 10-999
July 199596.8Fair6 out of 10-999
October 199296.8Fair6 out of 10-999
November 199096.8Fair6 out of 10-999