Share:

GREENTREE ROAD over BULLS RUN

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:GREENTREE ROAD over BULLS RUN
Structure number:200000M-0180020
Location:0.5 MI E OF JCT SR 191
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:12.1 ft. [3.7 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:30.2 ft. [9.2 m]
Deck width edge-to-edge:38.1 ft. [11.6 m]
Owner:County Highway Agency [02]
Year built:1949
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,175 [as of 2011]
Truck traffic:5% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:58.4 tons [53.1 metric tons]
Inventory rating:34.9 tons [31.7 metric tons]
Sufficiency rating:63.1

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201663.1Fair5 out of 10FO10175
June 201568.4Fair5 out of 10FO10175
June 201381.0Fair5 out of 10-10175
June 201181.2Fair5 out of 10-10175
June 200981.3Fair5 out of 10-9600
June 200781.3Fair5 out of 10-9600
June 200581.3Fair5 out of 10-9600
June 200381.3Fair5 out of 10-9600
June 200181.3Fair5 out of 10-9600
June 199981.5Fair5 out of 10-8930
June 199796.9Fair6 out of 10-8814
May 199597.0Fair6 out of 10-8814
May 199396.0Fair6 out of 10-8814
April 199184.7Fair5 out of 10-8814