Share:

I-95 RAMP O over RR TRACK, WETLANDS

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-95 RAMP O over RR TRACK, WETLANDS
Structure number:300000BCW563010
Location:MILEPOST M56.3
Purpose:Carries highway over railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:85.0 ft. [25.9 m]
Total length:1168.0 ft. [356.0 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:27.2 ft. [8.3 m]
Vertical clearance above deck:20.0 ft. [6.1 m]
Vertical clearance below bridge:25.9 ft. [7.9 m]
Skew angle:99°
Owner:State Toll Authority [31]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:15
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:9,776 [as of 2010]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:73.8 tons [67.1 metric tons]
Inventory rating:44.4 tons [40.4 metric tons]
Sufficiency rating:74.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201574.0GoodGoodGoodGoodFO9776
December 201374.0GoodGoodGoodGoodFO9776
February 201274.0GoodGoodGoodGoodFO9776
March 201174.0GoodGoodGoodGoodFO9776
February 201074.0GoodGoodGoodGoodFO9776
March 200995.7FairSatisfactorySatisfactoryGood-10000
March 200895.7GoodGoodGoodGood-10000
January 200795.7GoodGoodGoodGood-10000
January 200695.7GoodGoodGoodGood-10000
January 200498.0GoodGoodGoodGood--
March 200298.0GoodGoodGoodGood--
April 200098.0GoodGoodGoodGood--
February 199898.0GoodGoodGoodGood--
May 199698.0GoodGoodGoodGood--
December 199398.0GoodGoodVery GoodGood--

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.7,5627,562000
Steel Protective Coatingsq. ft.84,73284,732000
Deck
Reinforced Concrete Decksq. ft.56,50456,504000
Wearing Surfacessq. ft.49,95849,9055300
Substructure
Reinforced Concrete Columneach4242000
Reinforced Concrete Abutmentlinear ft.2828000
Reinforced Concrete Pier Caplinear ft.591591000
Joints
Strip Seal Jointlinear ft.470470000
Bearings
Elastomeric Bearingeach133133000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2,2232,223000