Share:

I-95 over SUSQUEHANNA RIVER,PA RR

Map

Coordinates:
+39.58418, -76.09789
39°35'03" N, 76°05'52" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-95 over SUSQUEHANNA RIVER,PA RR
Structure number:300000H-X907010
Location:HARFORD-CECIL CO LINE
Purpose:Carries highway over railroad and waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Tolls:Yes, on toll road [2]
Length of largest span:490.2 ft. [149.4 m]
Total length:5061.3 ft. [1542.6 m]
Roadway width between curbs:80.1 ft. [24.4 m]
Deck width edge-to-edge:87.3 ft. [26.6 m]
Vertical clearance below bridge:89.9 ft. [27.4 m]
Owner:State Toll Authority [31]
Year built:1963
Year reconstructed:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:11
Main spans material:Steel continuous [4]
Main spans design:Truss - Deck [09]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:85,780 [as of 2013]
Truck traffic:19% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:59.8 tons [54.4 metric tons]
Inventory rating:36.4 tons [33.1 metric tons]
Sufficiency rating:63.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201563.0FairSatisfactoryFairSatisfactoryFO85780
April 201463.0FairSatisfactoryFairSatisfactoryFO85780
February 201357.9FairSatisfactoryFairSatisfactoryFO77175
February 201157.9FairSatisfactoryFairSatisfactoryFO77175
May 200960.9FairSatisfactoryFairFair-74275
March 200871.9GoodGoodGoodGood-74275
April 200771.9GoodGoodGoodGood-74275
April 200671.9GoodGoodGoodGood-74275
April 200571.9GoodGoodGoodGood-74275
April 200471.9GoodGoodGoodGood-74275
May 200371.9GoodGoodGoodGood-74275
January 200271.9GoodGoodGoodGood-74275
May 200171.9GoodGoodGoodGood-56026
April 200071.9GoodGoodGoodGood-56026
February 199971.9GoodGoodGoodGood-56026
February 199871.9GoodGoodGoodGood-56026
March 199771.9GoodGoodGoodGood-56026
March 199671.9GoodGoodGoodGood-56026
February 199576.0GoodGoodGoodGood-56026
May 199476.0GoodGoodGoodGood-56026
March 199376.0GoodVery GoodGoodGood-56026
April 199076.0GoodVery GoodGoodGood-56026

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.3,0213,021000
Steel Protective Coatingsq. ft.29,86728,9773984920
Steel Stringerlinear ft.67,74567,745000
Steel Protective Coatingsq. ft.414,644372,44042,148560
Deck
Reinforced Concrete Decksq. ft.434,749434,749000
Superstructure
Steel Trusslinear ft.9,6809,680000
Steel Protective Coatingsq. ft.650,836563,52236,72932,54518,040
Steel Floor Beamlinear ft.13,82113,821000
Steel Protective Coatingsq. ft.200,316182,38110,7774,5072,651
Steel Pin or Pin & Hangar Assemblyeach120120000
Steel Gusset Plateeach636636000
Steel Protective Coatingsq. ft.51,19445,6802,5622,852100
Substructure
Reinforced Concrete Columneach2424000
Steel Column Tower/Trestlelinear ft.8080000
Steel Protective Coatingsq. ft.7,2426,5165441820
Reinforced Concrete Pier Walllinear ft.8383000
Reinforced Concrete Abutmentlinear ft.174174000
Steel Pier Caplinear ft.160160000
Steel Protective Coatingsq. ft.3,3363,16916700
Reinforced Concrete Pier Caplinear ft.450450000
Joints
Strip Seal Jointlinear ft.2,0642,064000
Assembly without Seal Jointlinear ft.516516000
Bearings
Movable Bearingeach5252000
Steel Protective Coatingsq. ft.2,3002,2782110
Fixed Bearingeach5656000
Steel Protective Coatingsq. ft.1,7141,66826200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.15,16715,167000